1. NAME AND TITLE OF DATA LIBRARY
POINT97: A Temperature-Dependent, Linearly Interpolable, Tabulated Cross Section Library
Based on ENDF/B-VI, Release 4.
2. NAME AND TITLE OF DATA RETRIEVAL PROGRAMS
None included.
3. CONTRIBUTOR
Lawrence Livermore National Laboratory, Livermore, California.
4. HISTORICAL BACKGROUND AND INFORMATION
The ENDF/B data library, available from the National Nuclear Data Center (NNDC) at
Brookhaven National Laboratory, was recently updated to ENDF/B-VI, Release 4. These data were
processed into the form of temperature dependent cross sections at LLNL and are being distributed
as POINT97 by RSICC.
5. APPLICATION OF THE DATA
As distributed, the original evaluated data includes cross sections represented in the form of a
combination of resonance parameters and/or tabulated energy dependent cross sections, nominally at
0 Kelvin temperature. For use in applications, these ENDF/B-VI, Release 4 data were processed into
the form of temperature dependent cross sections at eight temperatures between 0 and 2100 Kelvin,
in steps of 300 Kelvin. At each temperature the cross sections are tabulated and linearly interpolable
in energy. The library contains data for 321 evaluations. The CCC-638/TART96 code package is recommended for
use with these data. Codes within TART96 can be used to display these data or to run calculations using these data.
6. SOURCE AND SCOPE OF DATA
The PREPRO97 code system was used to process the ENDF/B data. Listed below are the steps, including the PREPRO97 codes, which were used to process the data in the order in which the codes were run.
1) Linearly interpolable, tabulated cross sections (LINEAR)
2) Including the resonance contribution (RECENT)
3) Doppler broaden all cross sections to temperature (SIGMA1)
4) Check data, define redundant cross sections by summation (FIXUP).
Note that the reference ENDF/B data are available from NNDC and are not included on the CD-ROM.
7. DISCUSSION OF THE DATA RETRIEVAL PROGRAM
No data retrieval program is included in the package. The PREPRO97 code system has not been
released. Some modules from the PSR-365/PREPRO96 package may be used to plot the POINT97
data. The PSR-333/CHENDF6.9 code system for handling ENDF/B data may be used to access these
data.
8. DATA FORMAT AND COMPUTER
The data files, which were written on a PC, are in ENDF-B6 ASCII (character) format
(D00192/MNYCP/00).
9. TYPICAL RUNNING TIME
Not applicable.
10. REFERENCES
a. Documentation available with library:
D. E. Cullen, "A Temperature Dependent ENDF/B-VI, Release 4, Cross Section Library,"
UCRL-ID-127776 (July 4, 1997).
b. Other useful documentation:
D. E. Cullen, "The 1996 ENDF/B Pre-Processing Codes," IAEA-NDS-39, Rev. 9 (November
1996). PREPRO97 has not yet been released for distribution.
11. CONTENTS OF LIBRARY
The data are approximately one gigabyte in size and are distributed on two CD-ROM disks
written in DOS format.
12. DATE OF ABSTRACT
September 1997.
KEYWORDS: BASED ON ENDF/B-VI; EVALUATED NEUTRON CROSS SECTIONS.