RSICC Home Page

RSIC DATA LIBRARY DLC-159



1. NAME AND TITLE OF DATA LIBRARY

IRAN-LIB: P-3 Coupled Neutron-Gamma Cross Section Library in ISOTXS Format For Use with ANISN/PC (CCC-514).



2. NAME AND TITLE OF DATA RETRIEVAL PROGRAMS

LMOD: Selects materials from a master ASCII CCCC ISOTXS file and places them on a CCCC file for input to ANISN/PC (available in CCC-514/ANISN/PC).



3. CONTRIBUTORS

Atomic Energy Organization of Iran, Tehran, Iran,

Instituto de Pesquisas Energeticas Nucleares, Sao Paulo, Brasil,

through the NEA Data Bank, Gif-sur-Yvette Cedex, France.



4. HISTORICAL BACKGROUND AND INFORMATION

In order to solve a realistic shielding problem for either a neutron or gamma source, it is necessary to generate cross sections using AMPX-II (PSR-063) with the VITAMIN-4C (DLC-53) master library on a mainframe and then copy the generated cross section onto the ANISN/PC 'array 14 **'. This procedure is very cumbersome. In order to overcome the difficulty, IRAN-LIB was created. IRAN-LIB stands for Improved Range of ANISN/PC Library.



5. APPLICATION OF THE DATA

The library is designed for radiation shielding applications for use with CCC-514/IBMPC00/ANISN-PC.



6. SOURCE AND SCOPE OF DATA

The cross sections were taken from the VITAMIN-4C master library using the AMPX-II system and the ENDF/B-IV, ENDF/B-V and JENDL/3 master libraries using the NJOY (PSR-171) code. Since IRAN-LIB was developed mainly for shielding purposes, the elements selected for the library are those which are most encountered in shielding materials.



7. DISCUSSION OF THE DATA RETRIEVAL PROGRAMS

The module LMOD in CCC-514/ANISN/PC selects materials from the ISOTXS file and writes them on a CCCC file.



8. DATA FORMAT AND COMPUTER

Card images; IBM PC.



9. TYPICAL RUNNING TIME

The time required to create an H-1 library from IRAN1.LIB is about 30 seconds. Creating U-235 from the same library takes about 135 seconds.



10. REFERENCES

M. K. Marashi, J. R. Maiorino, A. G. Mendonca and A. Santos, "IRAN.LIB (Improved Range of ANISN/PC Library): A P-3 Coupled Neutron-Gamma Cross-Section Libraries in ISOTXS Format to be Used by ANISN/PC (CCC-514/02)," Instituto de Pesquisas Energeticas Nucleares, Sao Paulo, Brasil (October 10, 1990).

"Note to Recipients of ZZ-IRAN-LIB," Informal Notes, NEA Data Bank (November 26, 1990).

M. K. Marashi, J. R. Maiorino, A. G. Mendonca and A. Santos, "IRAN.LIB (Improved Range of ANISN/PC Library): A P-3 Coupled Neutron-Gamma Cross-Section Libraries in ISOTXS Format to be Used by ANISN/PC (CCC-514/02)," Ann. nucl. Energy, 18, p. 597-602 (1991).



11. CONTENTS OF PACKAGE

Included are the referenced documents, the data library and sample input and output. The data library is transmitted on one 3.5" (1.2MB) diskette in DOS self-extracting compressed files.



12. DATE OF ABSTRACT

March 1991, December 1993.



KEYWORDS: BASED ON ENDF/B; COUPLED NEUTRON-GAMMA-RAY CROSS SECTIONS; MULTIGROUP CROSS SECTIONS BASED ON ENDF/B; NEUTRON CROSS SECTIONS